A10-Y
The Quartzlock model A10-Y is an OEM, high-performance, ultra low noise, rubidium oscillator frequency reference which uses Quartzlock phase-locked loop (PLL) and direct digital synthesis (DDS) clean-up loop technology. It has a noise floor of -170 dBc/Hz.
Typical applications include but not restricted to Security, Low noise instrumentation reference, Radar navigation, RF & Microwave test solutions and Secure communications.
The use of ULN rubidium oscillators enables Weak signal detection, Low error rates, Higher radar sensitivity and Higher definition in MRI imaging systems.
Standard Specification:
Output Frequency10MHz
Output Level7
Number of Outputs1
STS1s5x10-12
STS10s 5x10-12
STS100s5x10-12
Aging 1 Month4x10-11
Aging 1 Year 5x10-10
Phase Noise 1Hz-110dBc
Phase Noise 10Hz-140dBc
Phase Noise 100Hz-145dBc
Phase Noise 1kHz -155dBc
Phase Noise 10kHz-157dBc
Harmonics dBc-30dBc
Warm Time5 min
Retrace<3x10-10
PSU Nominal 24
PSU Min 22
PSU Max30
OT Min -20
OT Max+50
Current2.5A
SupplyDC
ST Min-40
ST Max+70
Product Options:
This product can have the following options applied to
change its specification
Option 48.ELN - Extreme Low Noise Floor Output
Output Frequency50MHz ~ 100MHz
Output Level13dBm
Number of Outputs1
Aging 1 Year 0.5x10-6
Phase Noise 100Hz-137dBc
Phase Noise 1kHz -164dBc
Phase Noise 10kHz-178dBc
PSU Nominal 24
PSU Min 22
PSU Max30
OT Min -20
OT Max+50
Current2.5A
SupplyDC
ST Min-40
ST Max+70
Option 48.ULN - Ultra Low Noise Output
Output Frequency10MHz
Output Level7
Number of Outputs1
STS1s5x10-12
STS10s 3x10-12
STS100s5x10-12
Aging 1 Month4x10-11
Aging 1 Year 5x10-10
Phase Noise 1Hz-115dBc *1
Phase Noise 10Hz-146dBc *1
Phase Noise 100Hz-156dBc *1
Phase Noise 1kHz -163dBc *1
Phase Noise 10kHz-169dBc *1
Harmonics dBc-30dBc
Spurious dBc-80dBc
Warm Time5 min
Retrace<3x10-10
PSU Nominal 24
PSU Min 22
PSU Max30
OT Min -20
OT Max+50
Current2.5A
SupplyDC
ST Min-40
ST Max+70
*1 This specification is preliminary. Recommended test equipment – Quartzlock model A7-MX bb signal analyser with reference comparable to DUT; “clean” analog power supply. It’s assumed that phase noise test is performed under static conditions (no vibration), in still air, and care is taken for minimizing EMI.